Your position > HOME
Detail   Information
Multi Parameter Mass Flowmeter

$272Basic         
Interface
All features of the FMA6600 and FMA6700 Series flow meters can be accessed via the local four button keypad and LCD. The digital interface operates via RS485 (optional RS-232 available) and provides access to applicable internal data including: flow, temperature, pressure reading, auto zero, totalizer and alarms settings, gas table, conversion factors and engineering units selection, dynamic response compensation and linearization table adjustment. The analog interface provides 0 to 5 Vdc or 0 to 10 Vdc or 4 to 20 mA outputs for flow, pressure and temperature (jumper selectable).
Auto Zero
The FMA6600 and FMA6700 Series supports automatic sensor zero offset adjustment that can be activated locally via keypad or remotely via digital interface. The auto zero feature requires absolutely no flow through the meter during auto zero process. Provisions are made to either start, stop or save the current auto zero value via digital commands.
Totalizer
The total volume of the gas is calculated by integrating the actual gas flow rate with respect to time. Both keypad menu and digital interface commands are provided to: ?set the totalizer to ZERO ?start the totalizer at a preset flow ?assign action at a preset total volume ?start/stop totalizing the flow ?read totalizer Totalizer conditions become true, when the totalizer reading and the "Stop at Total" volumes are equal.
Flow Alarm
High and Low gas flow ALARM limits can be preprogrammed via keypad or remotely via digital interface. ALARM conditions become true when the current flow reading is equal or higher/lower than corresponding values of high and low alarm levels. Alarm action can be assigned with preset delay interval (0-3600 seconds) to activate the contact closer (separate for High and Low alarm). Pressure Alarm (FMA6700 Series) High and Low gas pressure ALARM limits can be preprogrammed via keypad or remotely via digital interface. Pressure alarm conditions become true when the current pressure reading is equal or higher than corresponding values of high pressure alarm settings or equal or lower than corresponding values of low pressure alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low pressure alarm). Temperature Alarm (FMA6700 Series) High and Low gas temperature ALARM limits can be preprogrammed via keypad or remotely via digital interface. Temperature alarm conditions become true when the current temperature reading is equal or higher than corresponding values of high temperature alarm settings or equal or lower than corresponding values of low temperature alarm settings. Alarm action can be assigned to activate the contact closer (separate for High and Low temperature alarm). 
 
Features
<> Multi-Drop Capability of Up to 256 Units (for RS-485 Option)
<> Stores Calibration Data for Up to 10 Different Gases
<> Supports 10 Different Engineering Units Including User Defined
<> Programmable 12 Digits Totalizer Indicates Total Gas Volume
<> Flow Alarm Limits for High and Low Gas Flow with Relay Output
<> Pressure Alarm (FMA6700) Limits for High and Low Gas Pressure with Relay Output
<> Temperature Alarm (FMA6700) Limits for High and Low Gas Temperature with Relay Output
<> Digital (RS-232 or RS-485) and Analog Outputs Operate Simultaneously
<> Internal Conversion Factors for Up to 32 Gases 
Related Document
 Technical Document 


Model Model Description Part No. Quantity
If you would like to have a quotation on the products, please input Quantity then click ¡ú
Back to Top

Quick Links

¡¡¡¡ Help
¡¡¡¡ Site Map

Company Information

¡¡¡¡ About GID
¡¡¡¡ Product Lines

Job Opportunity

¡¡¡¡ FAQS
¡¡¡¡ Student

Contact Information

¡¡¡¡ Location
¡¡¡¡ Message Board
Copyright ©  2020-2025 Geenbellon Group,LLC.    All Rights Reserved. ¡¡ICP: 13008204-3 | Term of Use   |   Privacy Policy